Not Tumbling
Admiral · AGD4475TQ1 7.0 cu ft Gas Dryer with Moisture Sensor and Wrinkle Guard
The dryer motor hums or runs but the drum does not rotate. The most common cause is a broken drum belt — a thin, flat belt that wraps around the outside of the drum. Access the belt by removing the top and front panels. Replace the belt and inspect the idler pulley bearing and drum rollers for wear. If the motor does not run at all, check the door switch, start switch, and thermal fuse.
Error Not Tumbling on the Admiral AGD4475TQ1 7.0 cu ft Gas Dryer with Moisture Sensor and Wrinkle Guard means: Motor Runs But Drum Does Not Turn. The top-ranked community fix is “Replace Broken Drum Belt and Inspect Rollers” (medium difficulty, ~60 min, DIY cost: $20-$30). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · dryer
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many dryer repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $150-$250.
Gas Odor When Dryer Is Running
Heat Works Then Stops Mid-Cycle
No Heat — Drum Turns But Clothes Stay Wet
Igniter Glows But Gas Does Not Ignite
Dryer Overheating or Burning Smell
Squeaking, Squealing, or Thumping Noise
Takes Too Long to Dry — Multiple Cycles Needed
Dryer Will Not Start
The Admiral AGD4475TQ1 7.0 cu ft Gas Dryer with Moisture Sensor and Wrinkle Guard has 8 other known error codes:
Error code Not Tumbling also appears on 1 other Admiral model: