No Ignition
Admiral · AGD4475TQ1 7.0 cu ft Gas Dryer with Moisture Sensor and Wrinkle Guard
The dryer's flat igniter glows bright orange through the sight window, but the gas valve never opens and no flame appears. This is the #1 gas dryer repair. The gas valve has 2-3 solenoid coils (booster coil + holding coils) that open the valve when the igniter reaches the proper temperature. These coils develop intermittent open circuits — they work when cold but fail as they heat up (resistance increases with temperature). The igniter cycles on and off repeatedly without ever producing a flame. Replace ALL gas valve solenoid coils as a set — never replace just one, as they wear at similar rates.
Error No Ignition on the Admiral AGD4475TQ1 7.0 cu ft Gas Dryer with Moisture Sensor and Wrinkle Guard means: Igniter Glows But Gas Does Not Ignite. The top-ranked community fix is “Replace All Gas Valve Solenoid Coils as a Set” (hard difficulty, ~90 min, DIY cost: $60-$90). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · dryer
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many dryer repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $200-$300.
Gas Odor When Dryer Is Running
Heat Works Then Stops Mid-Cycle
No Heat — Drum Turns But Clothes Stay Wet
Motor Runs But Drum Does Not Turn
Dryer Overheating or Burning Smell
Squeaking, Squealing, or Thumping Noise
Takes Too Long to Dry — Multiple Cycles Needed
Dryer Will Not Start
The Admiral AGD4475TQ1 7.0 cu ft Gas Dryer with Moisture Sensor and Wrinkle Guard has 8 other known error codes: