E01
Pentair · Pentair MasterTemp 400,000 BTU Gas Pool/Spa Heater
The heater failed to ignite after 3 attempts. The ignition module sends a spark to the burner while the gas valve opens — if no flame is detected by the flame sensing rod within the trial-for-ignition period, the heater shuts down with E01. Common causes include no gas supply (tank empty or gas valve off), a dirty or mispositioned flame sensing rod (the most common cause — clean with fine emery cloth), a faulty igniter (hot surface igniter cracked or weak spark igniter), spider webs or insect nests in the burner tray (very common in outdoor installations — mud daubers and spiders nest in burner orifices), or a faulty gas valve. Check gas supply first, then clean the flame rod, inspect the burner tray for debris, and verify the igniter is sparking.
Error E01 on the Pentair Pentair MasterTemp 400,000 BTU Gas Pool/Spa Heater means: Ignition Failure. The top-ranked community fix is “Test and Replace Faulty Water Temperature Thermistor Sensor” (medium difficulty, ~45 min, DIY cost: $15-$25). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · pool heater
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many pool heater repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $150-$220.
The Pentair Pentair MasterTemp 400,000 BTU Gas Pool/Spa Heater has 8 other known error codes:
Error code E01 also appears on 3 other Pentair models: