99
Rheem · Rheem RTGH-95DVLN Prestige 9.5 GPM Condensing Tankless Gas Water Heater
The main PCB has lost communication with the remote temperature controller or, in multi-unit installations, the cascade controller board. Check the communication wiring between the main unit and the remote controller — ensure connections are secure and wiring is not damaged. If using a multi-unit cascade system (multiple tankless heaters linked together), check the cascade controller and all inter-unit communication wiring. A standalone unit without a remote controller connected should not normally display this code — if it does, there may be a PCB fault or an incorrect DIP switch setting telling the unit to expect a remote controller.
Error 99 on the Rheem Rheem RTGH-95DVLN Prestige 9.5 GPM Condensing Tankless Gas Water Heater means: Communication Error — Remote Controller. The top-ranked community fix is “Test and Replace Main PCB or Remote Controller Board” (hard difficulty, ~60 min, DIY cost: $15-$20). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · water heater
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many water heater repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $250-$350.
False Flame Detection
Abnormal Combustion — Blocked Vent
Ignition Failure — No Flame Detected
Flame Failure — Flame Lost During Operation
Thermal Fuse Activated — Overheat Safety
Overheating — Outgoing Water Too Hot
Abnormal Temperature Rise — Low Water Flow
Condensate Drain / Vent Blockage
The Rheem Rheem RTGH-95DVLN Prestige 9.5 GPM Condensing Tankless Gas Water Heater has 8 other known error codes: