32
Rheem · Rheem RTGH-95DVLN Prestige 9.5 GPM Condensing Tankless Gas Water Heater
The thermistor (temperature sensor) that measures the hot water outlet temperature has failed. It is either reading open circuit, short circuit, or providing values outside the acceptable range. The unit cannot safely control the burner modulation rate without an accurate outlet temperature reading, so it shuts down. On RTGH models, the outlet thermistor is accessible by removing the front cover panel. Disconnect the sensor, measure its resistance with a multimeter (resistance should decrease predictably as temperature increases), and replace if readings are erratic, open (infinite), or shorted (near zero). Use the OEM replacement sensor for proper calibration.
Error 32 on the Rheem Rheem RTGH-95DVLN Prestige 9.5 GPM Condensing Tankless Gas Water Heater means: Outgoing Water Temperature Sensor Failure. The top-ranked community fix is “Test and Replace Outlet Water Temperature Sensor” (medium difficulty, ~45 min, DIY cost: $15-$25). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · water heater
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many water heater repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $120-$180.
False Flame Detection
Abnormal Combustion — Blocked Vent
Ignition Failure — No Flame Detected
Flame Failure — Flame Lost During Operation
Thermal Fuse Activated — Overheat Safety
Overheating — Outgoing Water Too Hot
Abnormal Temperature Rise — Low Water Flow
Condensate Drain / Vent Blockage
The Rheem Rheem RTGH-95DVLN Prestige 9.5 GPM Condensing Tankless Gas Water Heater has 8 other known error codes: