BLOWER CONTINUOUS
Rheem · Rheem R96V 96% AFUE Two-Stage Variable Speed Upflow Gas Furnace
The indoor blower fan runs nonstop and will not shut off. First check the thermostat fan setting — it should be set to AUTO, not ON. The ON setting runs the blower continuously regardless of heating/cooling demand. If the fan switch is already set to AUTO and the blower still runs continuously, the fan relay on the IFC board may be stuck closed, or the thermostat G (fan) wire may be shorted to the R (power) wire. To test: disconnect the G wire from the IFC board terminal strip. If the blower stops, the problem is in the thermostat or the wiring between the thermostat and furnace. If the blower continues running with G disconnected, the fan relay on the IFC board has failed and the board needs replacement.
Error BLOWER CONTINUOUS on the Rheem Rheem R96V 96% AFUE Two-Stage Variable Speed Upflow Gas Furnace means: Blower Motor Runs Continuously. The top-ranked community fix is “Test and Replace IFC Board Fan Relay if Needed” (hard difficulty, ~60 min, DIY cost: $0-$15). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · furnace
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many furnace repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $200-$350.
Normal — Heat Call Active
Rollout Switch Open
High-Stage Pressure Switch Open (Two-Stage Only)
System Lockout — Ignition Failed
Pressure Switch Stuck Closed
Pressure Switch Stuck Open
Flame Sensed Without Gas Valve Command
Power Reversed or No Ground
The Rheem Rheem R96V 96% AFUE Two-Stage Variable Speed Upflow Gas Furnace has 8 other known error codes:
Error code BLOWER CONTINUOUS also appears on 1 other Rheem model: