3 FLASH
Rheem · Rheem R96V 96% AFUE Two-Stage Variable Speed Upflow Gas Furnace
The pressure switch is reading as CLOSED before the inducer (draft) motor has started. The pressure switch monitors the draft created by the inducer motor and should only close when the inducer is running and creating proper airflow through the heat exchanger and vent. Possible causes: a faulty pressure switch with mechanically welded contacts, condensate (water) trapped in the pressure switch or its rubber hose — this is very common in condensing 90%+ AFUE furnaces that produce acidic condensate. Disconnect the pressure switch hose, drain any water, and reconnect. If the switch still reads closed with the hose disconnected, replace the pressure switch.
Error 3 FLASH on the Rheem Rheem R96V 96% AFUE Two-Stage Variable Speed Upflow Gas Furnace means: Pressure Switch Stuck Closed. The top-ranked community fix is “Replace Faulty Pressure Switch” (medium difficulty, ~45 min, DIY cost: $15-$25). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · furnace
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many furnace repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $150-$250.
Normal — Heat Call Active
Rollout Switch Open
High-Stage Pressure Switch Open (Two-Stage Only)
System Lockout — Ignition Failed
Pressure Switch Stuck Open
Flame Sensed Without Gas Valve Command
Power Reversed or No Ground
Low Flame Signal
The Rheem Rheem R96V 96% AFUE Two-Stage Variable Speed Upflow Gas Furnace has 8 other known error codes:
Error code 3 FLASH also appears on 1 other Rheem model: