BLOWER CONTINUOUS
Rheem · Rheem R801T 80% AFUE Single-Stage Upflow Gas Furnace
The blower runs nonstop. Check the thermostat fan switch — should be AUTO, not ON. If already on AUTO, the fan relay on the IFC board may be stuck or the G wire may be shorted to R. Disconnect the G wire at the furnace terminal strip to test.
Error BLOWER CONTINUOUS on the Rheem Rheem R801T 80% AFUE Single-Stage Upflow Gas Furnace means: Blower Motor Runs Continuously. The top-ranked community fix is “Test and Replace IFC Board Fan Relay if Needed” (hard difficulty, ~60 min, DIY cost: $0-$15). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · furnace
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many furnace repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $200-$350.