F1
Hotpoint · RGA724EKWH 5.0 cu ft 30 in Gas Range with Sealed Burners and Continuous Grates
The Electronic Range Control (ERC) board has an internal circuit failure — the control board cannot be repaired and must be replaced; disconnect power at the breaker for 60 seconds and restore; if F1 returns immediately, the ERC has a permanent hardware fault; make sure to order the correct ERC for your specific Hotpoint model number as different configurations use different boards even within the same series; the touch pad/keypad can also cause F1 on some models — if the touch pad is a separate component from the ERC, try disconnecting the touch pad ribbon cable from the ERC to isolate whether the fault is in the pad or the board
Error F1 on the Hotpoint RGA724EKWH 5.0 cu ft 30 in Gas Range with Sealed Burners and Continuous Grates means: Electronic Oven Control (ERC) Internal Failure. The top-ranked community fix is “Replace the Electronic Range Control (ERC) Board” (hard difficulty, ~60 min, DIY cost: $150-$200). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · oven
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many oven repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $300-$400.
Stuck Touch Pad Key
Oven Over-Temperature Condition
Open Oven Temperature Sensor (RTD Probe)
Shorted Oven Temperature Sensor (RTD Probe)
ERC Relay Board Failure
Stuck Function Key (Bake/Broil/Clean)
Oven Door Lock Motor or Switch Failure
Surface Burner Won't Light or Clicks Continuously
The Hotpoint RGA724EKWH 5.0 cu ft 30 in Gas Range with Sealed Burners and Continuous Grates has 8 other known error codes:
Error code F1 also appears on 2 other Hotpoint models: