E06
A.O. Smith · AHPTU-80 Voltex Hybrid 80 Gal 4500W Hybrid Heat Pump Water Heater with WiFi Connectivity
The condenser fan motor is not operating or is running at incorrect speed. The fan is essential for moving air across the evaporator coils in heat pump mode. Without the fan, the heat pump cannot extract heat from ambient air. Check for obstructions blocking the fan blades. Verify the fan motor wire connections. Test the fan motor by applying power directly — if it does not spin, replace the fan motor assembly.
Error E06 on the A.O. Smith AHPTU-80 Voltex Hybrid 80 Gal 4500W Hybrid Heat Pump Water Heater with WiFi Connectivity means: Condenser Fan Motor Failure. The top-ranked community fix is “Test and Replace the Condenser Fan Motor Assembly” (medium difficulty, ~60 min, DIY cost: $15-$25). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · water heater
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many water heater repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $150-$250.
The A.O. Smith AHPTU-80 Voltex Hybrid 80 Gal 4500W Hybrid Heat Pump Water Heater with WiFi Connectivity has 8 other known error codes:
Error code E06 also appears on 1 other A.O. Smith model:
Ad Space — banner