MECH-NO-HEAT
Whirlpool · Whirlpool WED5000DW 7.4 cu. ft. Electric Dryer
The dryer drum turns and the motor runs but no heat is produced. For electric dryers: check the heating element for continuity (2 terminals, should read 8-20 ohms); check both thermal fuses and the high-limit thermostat on the heater housing; verify 240V at the outlet. For gas dryers: check the igniter (it should glow bright orange) and gas valve coils. Whirlpool gas dryer igniters are a very common failure — they crack and fail to reach ignition temperature. The igniter draws current through the gas valve coils, so a weak igniter that glows but does not get hot enough will not open the gas valve.
Error MECH-NO-HEAT on the Whirlpool Whirlpool WED5000DW 7.4 cu. ft. Electric Dryer means: Dryer Runs But No Heat. The top-ranked community fix is “Test and Replace Heating Element and Thermal Fuses” (medium difficulty, ~60 min, DIY cost: $15-$30). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · dryer
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many dryer repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $120-$200.
Airflow Restricted
Main Control Board Error
Control Board Communication Error
Stuck Button on Control Panel
User Interface Board Failure
Exhaust Thermistor Open Circuit
Exhaust Thermistor Shorted
Inlet Thermistor Open Circuit
The Whirlpool Whirlpool WED5000DW 7.4 cu. ft. Electric Dryer has 8 other known error codes:
Error code MECH-NO-HEAT also appears on 1 other Whirlpool model:
Ad Space — banner
Replace ADSENSE_PUBLISHER_ID in AdUnit.tsx