HC2
Samsung · Samsung DVE45R6100W 7.5 cu. ft. Electric Dryer with Steam Sanitize+
Gas dryers only (DVG series). The gas igniter activated but flame was not detected within the expected time. The gas igniter (glow bar type on most Samsung gas dryers) heats up to open the gas valve, but if the igniter is weak (not reaching sufficient temperature), the gas valve will not open. Check the igniter — it should glow bright orange. A weak igniter glows dim orange or red. Also check the gas valve coils and flame sensor. Replace the igniter if it does not glow brightly.
Error HC2 on the Samsung Samsung DVE45R6100W 7.5 cu. ft. Electric Dryer with Steam Sanitize+ means: Gas Ignition Failure. The top-ranked community fix is “Replace Weak Igniter and Test Gas Valve Coils” (medium difficulty, ~45 min, DIY cost: $15-$30). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · dryer
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many dryer repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $120-$180.
The Samsung Samsung DVE45R6100W 7.5 cu. ft. Electric Dryer with Steam Sanitize+ has 8 other known error codes: