LED OFF
Rheem · Rheem R96V 96% AFUE Two-Stage Variable Speed Upflow Gas Furnace
The IFC (Integrated Furnace Control) board has no 24VAC power. The diagnostic LED is completely dark. Check the 115VAC supply to the furnace at the breaker and the furnace power switch (looks like a standard light switch, often on or near the furnace). Check the 3-amp fuse on the IFC board — remove and test for continuity. If the fuse is blown, identify the cause before replacing: common causes include a short in the thermostat wiring (R and C wires touching) or a failed 24VAC transformer. Test the transformer output with a multimeter — it should read 24-28 VAC.
Error LED OFF on the Rheem Rheem R96V 96% AFUE Two-Stage Variable Speed Upflow Gas Furnace means: No Power to Control Board. The top-ranked community fix is “Test and Replace 3-Amp Fuse and 24VAC Transformer” (hard difficulty, ~45 min, DIY cost: $15-$25). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · furnace
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many furnace repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $120-$180.
Normal — Heat Call Active
Rollout Switch Open
High-Stage Pressure Switch Open (Two-Stage Only)
System Lockout — Ignition Failed
Pressure Switch Stuck Closed
Pressure Switch Stuck Open
Flame Sensed Without Gas Valve Command
Power Reversed or No Ground
The Rheem Rheem R96V 96% AFUE Two-Stage Variable Speed Upflow Gas Furnace has 8 other known error codes:
Error code LED OFF also appears on 1 other Rheem model: