L9
Mitsubishi · MUZ-GL09NA 9,000 BTU Single-Zone Outdoor Unit
The compressor has failed to start within the allowed startup time. The inverter attempted to start the compressor but could not achieve rotation. Causes: seized compressor bearings, liquid refrigerant pooled in the compressor crankcase (liquid slugging), extremely low ambient temperature without crankcase heater, faulty inverter output stage, mechanical obstruction in the compressor. Try resetting power. If L9 recurs, check compressor winding resistance and insulation. In cold climates, ensure the crankcase heater is functioning before startup.
Error L9 on the Mitsubishi MUZ-GL09NA 9,000 BTU Single-Zone Outdoor Unit means: Compressor Startup Failure / Locked Rotor. The top-ranked community fix is “Test Compressor Windings and Replace Faulty Components” (hard difficulty, ~120 min, DIY cost: $0-$20). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · heat pump
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many heat pump repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $400-$700.
mini_split · 2 fixes
heat_pump · 2 fixes
heat_pump · 2 fixes
heat_pump · 2 fixes
heat_pump · 2 fixes
Reverse Phase / Phase Loss Detection
Compressor Discharge Temperature Protection
Outdoor Heat Exchanger Thermistor Error
Compressor Overheating / High Pressure Switch Activation
Outdoor Subcooling Sensor / Pipe Thermistor Error
High Head Pressure Protection
Compressor Overcurrent Protection (CT Sensor)
Heat Sink / Power Module Overheat Protection
The Mitsubishi MUZ-GL09NA 9,000 BTU Single-Zone Outdoor Unit has 8 other known error codes: