F8
Mitsubishi · MUZ-GL09NA 9,000 BTU Single-Zone Outdoor Unit
The current transformer (CT) sensor on the outdoor PCB has detected excessive current draw from the compressor motor. The indoor LED blinks 10 times. Causes: compressor bearing wear (common in aged units), locked rotor condition, incorrect supply voltage, short in compressor motor winding, liquid slugging (liquid refrigerant flooding back to compressor). Check supply voltage at the outdoor unit terminals. Measure compressor winding resistance phase-to-phase. Check for liquid refrigerant in the suction line.
Error F8 on the Mitsubishi MUZ-GL09NA 9,000 BTU Single-Zone Outdoor Unit means: Compressor Overcurrent Protection (CT Sensor). The top-ranked community fix is “Test Compressor Windings and Replace Compressor if Faulty” (hard difficulty, ~120 min, DIY cost: $0-$15). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · heat pump
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many heat pump repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $900-$1200.
mini_split · 2 fixes
heat_pump · 2 fixes
heat_pump · 2 fixes
heat_pump · 2 fixes
heat_pump · 2 fixes
Reverse Phase / Phase Loss Detection
Compressor Discharge Temperature Protection
Outdoor Heat Exchanger Thermistor Error
Compressor Overheating / High Pressure Switch Activation
Outdoor Subcooling Sensor / Pipe Thermistor Error
High Head Pressure Protection
Heat Sink / Power Module Overheat Protection
High Pressure Switch (63H) Activated
The Mitsubishi MUZ-GL09NA 9,000 BTU Single-Zone Outdoor Unit has 8 other known error codes: