4 FLASHES
Lennox · SL280V Dave Lennox Signature Collection 80% AFUE Variable Speed Gas Furnace
The draft inducer motor is running but the pressure switch did not close within the expected time. This is one of the most common Lennox furnace fault codes. Causes: blocked exhaust vent (ice, bird nest, debris), clogged condensate drain (high-efficiency 90%+ units), cracked or kinked pressure switch hose, weak or failing draft inducer motor, or a bad pressure switch. Check the exhaust vent termination outside the home first — #1 cause in winter.
Error 4 FLASHES on the Lennox SL280V Dave Lennox Signature Collection 80% AFUE Variable Speed Gas Furnace means: Pressure Switch Open — Did Not Close. The top-ranked community fix is “Test and Replace Pressure Switch or Draft Inducer Motor” (hard difficulty, ~75 min, DIY cost: $30-$50). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · furnace
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many furnace repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $150-$220.
No Previous Fault Code Stored
Blower Motor Calibration Fault
Auxiliary Limit Switch Open
Inducer Motor Fault
Communicating System Fault
System Lockout — Retries Exhausted
Pressure Switch Stuck Closed
Flame Sensed Without Call for Heat
The Lennox SL280V Dave Lennox Signature Collection 80% AFUE Variable Speed Gas Furnace has 8 other known error codes:
Error code 4 FLASHES also appears on 3 other Lennox models:
Ad Space — banner
Replace ADSENSE_PUBLISHER_ID in AdUnit.tsx