12 FLASHES
Lennox · SL280V Dave Lennox Signature Collection 80% AFUE Variable Speed Gas Furnace
The draft inducer motor did not start or is not running at the expected speed. Causes: failed inducer motor (bearings worn, windings open), inducer motor capacitor failed (if equipped), control board inducer output failure, or wiring issue. If it hums but doesn't spin, the bearings are likely seized. Replace the inducer motor assembly. Typical lifespan 10–15 years.
Error 12 FLASHES on the Lennox SL280V Dave Lennox Signature Collection 80% AFUE Variable Speed Gas Furnace means: Inducer Motor Fault. The top-ranked community fix is “Test and Replace Inducer Motor Assembly” (hard difficulty, ~90 min, DIY cost: $0-$20). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · furnace
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many furnace repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $250-$400.