6 FLASHES
Lennox · EL296V Elite Series 96% AFUE Two-Stage Variable Speed Gas Furnace
The control board has detected reversed line voltage polarity (hot and neutral swapped) or an improper ground connection. Lennox furnace controls require correct polarity for flame sensing to work properly. The flame sense circuit uses the grounding path as a reference. Check the power supply: hot wire on the black terminal, neutral on white, and proper earth ground. Use a multimeter to verify proper polarity at the furnace junction box.
Error 6 FLASHES on the Lennox EL296V Elite Series 96% AFUE Two-Stage Variable Speed Gas Furnace means: 115 VAC Power or Ground Fault. The top-ranked community fix is “Inspect and Repair Grounding and Control Board Connections” (medium difficulty, ~45 min, DIY cost: $0-$10). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · furnace
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many furnace repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $120-$200.
No Previous Fault Code Stored
Blower Motor Calibration Fault
Auxiliary Limit Switch Open
Inducer Motor Fault
Communicating System Fault
System Lockout — Retries Exhausted
Pressure Switch Stuck Closed
Pressure Switch Open — Did Not Close
The Lennox EL296V Elite Series 96% AFUE Two-Stage Variable Speed Gas Furnace has 8 other known error codes:
Error code 6 FLASHES also appears on 3 other Lennox models: