3 FLASHES
Lennox · EL296V Elite Series 96% AFUE Two-Stage Variable Speed Gas Furnace
The pressure switch is reading closed when it should be open (inducer motor is NOT running). This can indicate a stuck pressure switch, a shorted pressure switch wire, or a pressure switch hose connected to the wrong port. The draft inducer must be off and the pressure switch should be open before the ignition sequence begins. Replace the pressure switch if contacts are welded shut.
Error 3 FLASHES on the Lennox EL296V Elite Series 96% AFUE Two-Stage Variable Speed Gas Furnace means: Pressure Switch Stuck Closed. The top-ranked community fix is “Test and Replace Faulty Pressure Switch” (hard difficulty, ~60 min, DIY cost: $20-$30). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · furnace
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many furnace repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $130-$180.
No Previous Fault Code Stored
Blower Motor Calibration Fault
Auxiliary Limit Switch Open
Inducer Motor Fault
Communicating System Fault
System Lockout — Retries Exhausted
Pressure Switch Open — Did Not Close
Flame Sensed Without Call for Heat
The Lennox EL296V Elite Series 96% AFUE Two-Stage Variable Speed Gas Furnace has 8 other known error codes:
Error code 3 FLASHES also appears on 3 other Lennox models: