F31
Kenmore · 110.65132 7.0 cu. ft. Electric Dryer with Wrinkle Guard
Low or missing voltage on one leg of 240V circuit. Check circuit breaker — one pole may have tripped. Check dryer power cord connections at terminal block. Verify outlet reads 240V across L1-L2.
Error F31 on the Kenmore 110.65132 7.0 cu. ft. Electric Dryer with Wrinkle Guard means: Low Voltage (L2 Leg) Detected. The top-ranked community fix is “Test Voltage and Replace Dryer Power Cord” (hard difficulty, ~60 min, DIY cost: $20-$35). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · dryer
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many dryer repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $150-$220.
Airflow Restriction Detected
Dryer Belt Broken
Drum Glides / Slides Worn
Drum Rollers Squeaking/Thumping
Heating Element Burned Out
Main Control Board EEPROM Error
Keypad / User Interface Fault
Exhaust Thermistor Fault
The Kenmore 110.65132 7.0 cu. ft. Electric Dryer with Wrinkle Guard has 8 other known error codes:
Error code F31 also appears on 1 other Kenmore model: