ELEMENT BURNED OUT
Kenmore · 110.65132 7.0 cu. ft. Electric Dryer with Wrinkle Guard
Dryer runs but no heat, clothes take forever. Check element continuity — should read ~10 ohms, reads infinite if burned out. Replace element assembly. Also check high-limit thermostat and thermal fuse.
Error ELEMENT BURNED OUT on the Kenmore 110.65132 7.0 cu. ft. Electric Dryer with Wrinkle Guard means: Heating Element Burned Out. The top-ranked community fix is “Replace Heating Element and Check Safety Thermostats” (hard difficulty, ~90 min, DIY cost: $20-$40). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · dryer
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many dryer repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $180-$300.
Airflow Restriction Detected
Dryer Belt Broken
Drum Glides / Slides Worn
Drum Rollers Squeaking/Thumping
Main Control Board EEPROM Error
Keypad / User Interface Fault
Exhaust Thermistor Fault
Exhaust Thermistor Short Circuit
The Kenmore 110.65132 7.0 cu. ft. Electric Dryer with Wrinkle Guard has 8 other known error codes:
Error code ELEMENT BURNED OUT also appears on 1 other Kenmore model: