E5B
Frigidaire · FCED4900HW 8.0 cu ft Electric Dryer with Quick Dry
The dryer door switch indicates the door is open. Close the door firmly until it clicks. If closed but the error persists, test the door switch for continuity with a multimeter when closed — it should show continuity. Check the door strike for wear or misalignment. Replace the door switch if it does not make contact when the door is closed.
Error E5B on the Frigidaire FCED4900HW 8.0 cu ft Electric Dryer with Quick Dry means: Door Switch Open — Door Not Closed. The top-ranked community fix is “Test and Replace Door Switch Assembly” (medium difficulty, ~30 min, DIY cost: $15-$25). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · dryer
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many dryer repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $120-$180.
dryer · 2 fixes
dryer · 2 fixes
dryer · 2 fixes
dryer · 2 fixes
washer · 2 fixes
dryer · 2 fixes
Inlet Thermistor Open or Shorted
Outlet Thermistor Open or Shorted
Motor Start Failure
Heater Relay Not Closing
Heater Relay Stuck On — FIRE HAZARD
Heating Element Open Circuit
Heater Relay Stuck — Multiple Trips
Stuck Heater Relay — Safety Shutdown
The Frigidaire FCED4900HW 8.0 cu ft Electric Dryer with Quick Dry has 8 other known error codes:
Error code E5B also appears on 6 other Frigidaire models: