RAPID-FLASH
Carrier · Carrier 59TP6A080E17 80,000 BTU 96% AFUE Two-Stage Gas Furnace with Variable-Speed Blower
The furnace control board LED flashes rapidly and continuously (not a counted pattern). This indicates the flame sensor is detecting flame but the signal strength is below the minimum acceptable threshold (typically less than 1 microamp on Carrier furnaces; normal is 2-6 microamps). The furnace may run but shut down intermittently when the flame signal dips too low. This is almost always caused by a dirty flame sensor rod — carbon buildup on the sensor reduces its ability to conduct the flame-proving current. Remove the flame sensor (one 1/4" hex screw) and clean the metal sensing rod with fine emery cloth, steel wool, or a dollar bill (the abrasive in currency paper works well). Other causes: weak gas pressure causing a small flame, cracked heat exchanger allowing flame to dance away from the sensor, or a coating on the sensor from combustion byproducts in homes with chemical exposure (hair spray, cleaning products near the furnace return).
Error RAPID-FLASH on the Carrier Carrier 59TP6A080E17 80,000 BTU 96% AFUE Two-Stage Gas Furnace with Variable-Speed Blower means: LED Rapid Flashing — Flame Signal Below Threshold. The top-ranked community fix is “Test and Replace the Flame Sensor Rod” (medium difficulty, ~30 min, DIY cost: $20-$50). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · furnace
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many furnace repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $150-$250.
LED 1 Blink — System Lockout (Retries Exceeded)
LED 10 Blinks — Secondary Limit Switch Open (Condensing)
LED 2 Blinks — Pressure Switch Stuck Closed
LED 3 Blinks — Pressure Switch Did Not Close (Draft Safeguard)
LED 4 Blinks — Open High-Limit Switch (Overheating)
LED 5 Blinks — Flame Sensed Without Gas Valve Call (Dangerous)
LED 6 Blinks — 115V Power Reversed or Neutral Not Grounded
LED 7 Blinks — Gas Valve Circuit Failure
The Carrier Carrier 59TP6A080E17 80,000 BTU 96% AFUE Two-Stage Gas Furnace with Variable-Speed Blower has 8 other known error codes: