BLINK-10
Carrier · Carrier 59TP6A080E17 80,000 BTU 96% AFUE Two-Stage Gas Furnace with Variable-Speed Blower
The furnace control board LED flashes 10 times, pauses, then repeats. The secondary high-limit switch has opened due to excessive temperature in the secondary heat exchanger area. This code is specific to condensing furnaces (90%+ AFUE) that have a secondary heat exchanger to extract additional heat from the exhaust gases. The secondary limit switch protects this component from overheating. Causes: (1) Blocked condensate drain — the secondary heat exchanger produces acidic condensate that must drain freely. If the drain line or trap is clogged, condensate backs up and overheats. Clear the drain with a wet/dry vacuum or pipe cleaner. (2) Failed secondary heat exchanger — internal corrosion can restrict flue gas flow. (3) Restricted airflow (dirty filter, blocked vents) causing both primary and secondary heat exchangers to overheat. (4) Failed secondary limit switch — the switch itself may need replacement.
Error BLINK-10 on the Carrier Carrier 59TP6A080E17 80,000 BTU 96% AFUE Two-Stage Gas Furnace with Variable-Speed Blower means: LED 10 Blinks — Secondary Limit Switch Open (Condensing). The top-ranked community fix is “Test and Replace the Secondary Limit Switch” (medium difficulty, ~45 min, DIY cost: $15-$50). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · furnace
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many furnace repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $150-$250.
LED 1 Blink — System Lockout (Retries Exceeded)
LED 2 Blinks — Pressure Switch Stuck Closed
LED 3 Blinks — Pressure Switch Did Not Close (Draft Safeguard)
LED 4 Blinks — Open High-Limit Switch (Overheating)
LED 5 Blinks — Flame Sensed Without Gas Valve Call (Dangerous)
LED 6 Blinks — 115V Power Reversed or Neutral Not Grounded
LED 7 Blinks — Gas Valve Circuit Failure
LED 8 Blinks — Ignitor Circuit Fault / Low Flame Signal
The Carrier Carrier 59TP6A080E17 80,000 BTU 96% AFUE Two-Stage Gas Furnace with Variable-Speed Blower has 8 other known error codes: