BLINK-8
Carrier · Carrier 59TP6A080E17 80,000 BTU 96% AFUE Two-Stage Gas Furnace with Variable-Speed Blower
The furnace control board LED flashes 8 times, pauses, then repeats. The control board detected either an open ignitor circuit (the hot surface ignitor is not drawing expected electrical current) or the flame signal during operation is too low. This dual-purpose code is one of the most commonly encountered on Carrier furnaces. For ignitor issues: the hot surface ignitor may be cracked (visible hairline fracture — especially on older silicon carbide ignitors that are very fragile). Check continuity with a multimeter — a good ignitor reads 40-200 ohms depending on type. Replacement ignitors cost $15-$80. For low flame signal issues: the flame sensor rod is dirty with carbon buildup — this is the #1 furnace service call nationwide. Remove the flame sensor (single 1/4" hex screw), clean the metal rod with fine emery cloth or steel wool until shiny, and reinstall. A clean flame sensor should produce 2-6 microamps of DC current in the flame.
Error BLINK-8 on the Carrier Carrier 59TP6A080E17 80,000 BTU 96% AFUE Two-Stage Gas Furnace with Variable-Speed Blower means: LED 8 Blinks — Ignitor Circuit Fault / Low Flame Signal. The top-ranked community fix is “Test and Replace Hot Surface Ignitor” (medium difficulty, ~60 min, DIY cost: $15-$80). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · furnace
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many furnace repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $150-$300.
LED 1 Blink — System Lockout (Retries Exceeded)
LED 10 Blinks — Secondary Limit Switch Open (Condensing)
LED 2 Blinks — Pressure Switch Stuck Closed
LED 3 Blinks — Pressure Switch Did Not Close (Draft Safeguard)
LED 4 Blinks — Open High-Limit Switch (Overheating)
LED 5 Blinks — Flame Sensed Without Gas Valve Call (Dangerous)
LED 6 Blinks — 115V Power Reversed or Neutral Not Grounded
LED 7 Blinks — Gas Valve Circuit Failure
The Carrier Carrier 59TP6A080E17 80,000 BTU 96% AFUE Two-Stage Gas Furnace with Variable-Speed Blower has 8 other known error codes:
Error code BLINK-8 also appears on 3 other Carrier models: