MECH-IGNITOR
Carrier · Carrier 59TN6 Infinity 96 Two-Stage 96% AFUE Gas Furnace with Variable-Speed Blower
The furnace inducer runs and the pressure switch closes, but the ignitor does not glow and the burners never light. The hot surface ignitor (HSI) is a ceramic element that heats to ~1,800°F to ignite the gas. Carrier furnaces use either silicon carbide (older, very fragile, dark gray) or silicon nitride (newer, more durable, white/light gray) ignitors. These fail from thermal cycling — they crack from repeatedly heating and cooling over thousands of cycles. To diagnose: with power off, visually inspect the ignitor for cracks (even hairline cracks are fatal). Test with a multimeter — a good ignitor reads 40-200 ohms; an open reading means it's cracked. Replacement is straightforward DIY: turn off power and gas, remove the 2 mounting screws, disconnect the wire plug, install the new ignitor (never touch the ceramic element with bare fingers — oil from skin creates hot spots that cause premature failure). Parts cost $15-$80 depending on the model.
Error MECH-IGNITOR on the Carrier Carrier 59TN6 Infinity 96 Two-Stage 96% AFUE Gas Furnace with Variable-Speed Blower means: Hot Surface Ignitor Failure — Furnace Won't Ignite. The top-ranked community fix is “Test and Replace the Hot Surface Ignitor” (medium difficulty, ~30 min, DIY cost: $15-$80). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · furnace
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many furnace repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $150-$250.
furnace · 2 fixes
furnace · 2 fixes
furnace · 2 fixes
furnace · 2 fixes
furnace · 2 fixes
Infinity Code 21 — Gas Heating Lockout
Infinity Code 22 — Abnormal Flame-Proving Signal
Infinity Code 23 — Pressure Switch Fault
Infinity Code 24 — Secondary Voltage Fuse Blown
Infinity Code 26 — Line Voltage Limit Circuit Open
Infinity Code 41 — Blower Motor Fault
Infinity Code 42 — Inducer Motor Fault
Infinity Code 43 — Low Flame Signal / Dirty Flame Sensor
The Carrier Carrier 59TN6 Infinity 96 Two-Stage 96% AFUE Gas Furnace with Variable-Speed Blower has 8 other known error codes:
Error code MECH-IGNITOR also appears on 5 other Carrier models: