BLINK-9
Carrier · Carrier 58STA/STX 80,000 BTU 80% AFUE Single-Stage Upflow Gas Furnace
The furnace control board LED flashes 9 times, pauses, then repeats. This is an alternate grounding/polarity fault code that appears on some Carrier furnace models. Similar to the 6-blink code, it indicates improper electrical grounding or reversed polarity at the furnace's power supply. On some Carrier models, 9 blinks specifically indicates that the ground and neutral are not properly bonded, even if polarity appears correct. Verify: (1) The furnace has a proper equipment ground wire connected. (2) The electrical panel has a proper neutral-to-ground bond (main panel only). (3) Using a multimeter, check for voltage between neutral and ground at the furnace — it should be near zero volts. Any significant voltage indicates a wiring problem. (4) If the furnace is plugged into an outlet, try a different outlet. If hard-wired, have the circuit checked by an electrician. Portable generators without proper grounding can also trigger this code.
Error BLINK-9 on the Carrier Carrier 58STA/STX 80,000 BTU 80% AFUE Single-Stage Upflow Gas Furnace means: LED 9 Blinks — Check Grounding / Reversed Polarity. The top-ranked community fix is “Verify Furnace Grounding and Neutral-to-Ground Bond at Electrical Panel” (hard difficulty, ~60 min, DIY cost: $0-$20). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · furnace
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many furnace repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $150-$300.
LED 1 Blink — System Lockout (Retries Exceeded)
LED 2 Blinks — Pressure Switch Stuck Closed
LED 3 Blinks — Pressure Switch Did Not Close (Draft Safeguard)
LED 4 Blinks — Open High-Limit Switch (Overheating)
LED 5 Blinks — Flame Sensed Without Gas Valve Call (Dangerous)
LED 6 Blinks — 115V Power Reversed or Neutral Not Grounded
LED 7 Blinks — Gas Valve Circuit Failure
LED 8 Blinks — Ignitor Circuit Fault / Low Flame Signal
The Carrier Carrier 58STA/STX 80,000 BTU 80% AFUE Single-Stage Upflow Gas Furnace has 8 other known error codes: