BLINK-4
Carrier · Carrier 58STA/STX 80,000 BTU 80% AFUE Single-Stage Upflow Gas Furnace
The furnace control board LED flashes 4 times, pauses, then repeats. The primary high-limit safety switch has opened because the temperature inside the heat exchanger exceeded safe limits. The furnace shuts down to prevent damage to the heat exchanger and potential safety hazards. This is the MOST COMMON cause of a furnace that runs for a few minutes then shuts off. Causes (in order of likelihood): (1) DIRTY AIR FILTER — the #1 cause. A clogged filter restricts airflow through the heat exchanger, causing it to overheat. Replace the filter immediately. (2) Blocked or closed supply/return vents — ensure all registers in the home are open and unblocked by furniture. (3) Failed blower motor — if the blower isn't running or is running too slowly, heat builds up. Check if you hear the blower running. (4) Blower wheel dirty or clogged — remove the blower assembly and check for dirt/debris on the squirrel cage wheel. (5) Undersized ductwork — if ducts are too small for the furnace BTU rating, chronic overheating occurs.
Error BLINK-4 on the Carrier Carrier 58STA/STX 80,000 BTU 80% AFUE Single-Stage Upflow Gas Furnace means: LED 4 Blinks — Open High-Limit Switch (Overheating). The top-ranked community fix is “Inspect and Clean Blower Assembly and Verify Blower Motor Operation” (hard difficulty, ~90 min, DIY cost: $0-$15). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · furnace
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many furnace repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $150-$300.
LED 1 Blink — System Lockout (Retries Exceeded)
LED 2 Blinks — Pressure Switch Stuck Closed
LED 3 Blinks — Pressure Switch Did Not Close (Draft Safeguard)
LED 5 Blinks — Flame Sensed Without Gas Valve Call (Dangerous)
LED 6 Blinks — 115V Power Reversed or Neutral Not Grounded
LED 7 Blinks — Gas Valve Circuit Failure
LED 8 Blinks — Ignitor Circuit Fault / Low Flame Signal
LED 9 Blinks — Check Grounding / Reversed Polarity
The Carrier Carrier 58STA/STX 80,000 BTU 80% AFUE Single-Stage Upflow Gas Furnace has 8 other known error codes: