5-FLASH
Bradford White · RG240T6N eF Series
The ICON System LED blinks five times, indicating the temperature sensor (thermistor) inside the gas control valve is reading an open or short circuit. The gas valve cannot monitor water temperature and will not allow the burner to fire as a safety precaution. The thermistor is built into the gas control valve on Bradford White ICON System models — it is not a separately replaceable part. If the 5-flash code appears, the entire gas control valve assembly must be replaced. Before replacing, check the wiring connector on the gas valve for loose or corroded pins.
Error 5-FLASH on the Bradford White RG240T6N eF Series means: Temperature Sensor Failure. The top-ranked community fix is “Replace Entire Gas Control Valve Assembly” (hard difficulty, ~90 min, DIY cost: $150-$250). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · water heater
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many water heater repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $350-$500.
water_heater · 2 fixes
water_heater · 2 fixes
water_heater · 2 fixes
water_heater · 2 fixes
water_heater · 2 fixes
water_heater · 2 fixes
Normal Operation — System OK
Thermopile Voltage Low
High Temperature / ECO Trip
Gas Control Valve Electronics Failure
Power Interruption / Loss of Pilot Signal
No Power to Gas Control — LED Dark
Anode Rod Depleted — Rotten Egg Smell or Corrosion
Broken Dip Tube — Lukewarm Water
The Bradford White RG240T6N eF Series has 8 other known error codes:
Error code 5-FLASH also appears on 6 other Bradford White models: