2-FLASH
Bradford White · RG240T6N eF Series
The ICON System LED blinks twice, indicating the thermopile is generating insufficient millivoltage (below ~400mV) to hold the gas valve open. The pilot may extinguish or the main burner will not fire. The thermopile is a sensor in the pilot flame that generates electrical power to operate the gas valve — no external electricity is needed. Clean the thermopile with fine sandpaper or emery cloth, making sure the pilot flame is fully engulfing the tip. Check the thermopile wiring connections at the gas valve. If voltage remains below 400mV with the pilot lit, replace the thermopile. Also check that the pilot flame is strong and blue — a weak yellow flame indicates a clogged pilot orifice or air supply issue.
Error 2-FLASH on the Bradford White RG240T6N eF Series means: Thermopile Voltage Low. The top-ranked community fix is “Test and Replace Thermopile Sensor” (medium difficulty, ~45 min, DIY cost: $20-$30). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · water heater
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many water heater repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $150-$250.
water_heater · 2 fixes
water_heater · 2 fixes
water_heater · 2 fixes
water_heater · 2 fixes
water_heater · 2 fixes
water_heater · 2 fixes
Normal Operation — System OK
High Temperature / ECO Trip
Temperature Sensor Failure
Gas Control Valve Electronics Failure
Power Interruption / Loss of Pilot Signal
No Power to Gas Control — LED Dark
Anode Rod Depleted — Rotten Egg Smell or Corrosion
Broken Dip Tube — Lukewarm Water
The Bradford White RG240T6N eF Series has 8 other known error codes:
Error code 2-FLASH also appears on 6 other Bradford White models: