MECH-NO-HOT-WATER
Bradford White · RE340S6 40 Gallon 4500W Short Electric Water Heater with Glass Lining
The water heater is producing no hot water at all. On electric models, check: Is the circuit breaker tripped? Reset it and wait for recovery. Has the ECO tripped? (Press the red reset button on the upper thermostat.) Is the upper heating element working? (Test for 12-13 ohms resistance.) Is the upper thermostat working? (Test for voltage at the element terminals.) Check for a tripped GFCI breaker or a loose wire connection at the breaker or at the water heater junction box. Verify 240V power at the top of the upper thermostat with a multimeter. A complete loss of hot water on an electric model almost always points to a power problem, tripped ECO, or failed upper element.
Error MECH-NO-HOT-WATER on the Bradford White RE340S6 40 Gallon 4500W Short Electric Water Heater with Glass Lining means: No Hot Water — Complete Loss. The top-ranked community fix is “Test and Replace Thermopile or Dip Tube” (hard difficulty, ~90 min, DIY cost: $15-$40). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · water heater
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many water heater repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $150-$250.
water_heater · 2 fixes
water_heater · 2 fixes
water_heater · 2 fixes
water_heater · 2 fixes
water_heater · 2 fixes
water_heater · 2 fixes
water_heater · 2 fixes
water_heater · 2 fixes
Anode Rod Depleted — Rotten Egg Smell or Corrosion
ECO (Energy Cut Off) Tripped — Red Reset Button
Lower Heating Element Failed
Upper Heating Element Failed
Not Enough Hot Water — Runs Out Quickly
Tank Leaking from Bottom
Sediment Buildup — Popping Noise or Reduced Efficiency
Thermostat Failure — Wrong Temperature
The Bradford White RE340S6 40 Gallon 4500W Short Electric Water Heater with Glass Lining has 8 other known error codes:
Error code MECH-NO-HOT-WATER also appears on 8 other Bradford White models: