The water heater produces no hot water at all. On gas models, check: Is the pilot lit? (Look through the sight glass — you should see a small blue flame.) If not, follow the pilot lighting instructions on the label. Check that the gas supply valve (handle on the gas line) is fully open. Verify the thermostat dial on the gas control is set to a temperature setting (not PILOT or OFF). If the pilot is lit but the burner never fires, the thermopile voltage may be low (see 2-FLASH code). Also check the gas supply — other gas appliances in the home should work. If the burner fires but water is still cold, the dip tube may be broken.
Error MECH-NO-HOT-WATER on the Bradford White MI50S6BN 50 Gallon 76,000 BTU Magnum Series Commercial Natural Gas Water Heater means: No Hot Water. The top-ranked community fix is “Test and Replace Thermopile or Dip Tube” (hard difficulty, ~90 min, DIY cost: $15-$40). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · water heater
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many water heater repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $150-$250.
water_heater · 2 fixes
water_heater · 2 fixes
water_heater · 2 fixes
water_heater · 2 fixes
water_heater · 2 fixes
water_heater · 2 fixes
water_heater · 2 fixes
water_heater · 2 fixes
Normal Operation — System OK
Thermopile Voltage Low
High Temperature / ECO Trip
Temperature Sensor Failure
Gas Control Valve Electronics Failure
Power Interruption / Loss of Pilot Signal
No Power to Gas Control — LED Dark
Anode Rod Depleted — Rotten Egg Smell or Corrosion
The Bradford White MI50S6BN 50 Gallon 76,000 BTU Magnum Series Commercial Natural Gas Water Heater has 8 other known error codes:
Error code MECH-NO-HOT-WATER also appears on 8 other Bradford White models: