Continuous Click
Bosch · HGS8655UC 800 Series 36 in Gas Cooktop
The spark igniters continue to click even when all burners are turned off. The most common cause is moisture around the igniter electrodes — after boiling over or cleaning the cooktop with water, moisture can create a path that triggers continuous sparking. Dry the area around each igniter thoroughly. Turn off the circuit breaker and allow the cooktop to dry for several hours. If clicking continues after drying, a burner switch may be stuck or shorted. The spark module may need replacement if it is continuously energized.
Error Continuous Click on the Bosch HGS8655UC 800 Series 36 in Gas Cooktop means: Igniters Click Continuously When Off. The top-ranked community fix is “Replace Faulty Burner Switch or Spark Module” (medium difficulty, ~45 min, DIY cost: $10-$25). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · cooktop
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many cooktop repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $150-$220.
The Bosch HGS8655UC 800 Series 36 in Gas Cooktop has 5 other known error codes: