E021
Bosch · HGI8056UC 800 Series 30 in Gas Slide-In Range
The gas igniter for the broil burner (top of oven) is not reaching sufficient temperature. Same diagnosis as E020 but for the broil circuit. Check the broil igniter for cracks (visible through the oven — the igniter should glow bright orange). Measure amperage draw. Replace if weak or failed. On dual-oven models, the upper and lower ovens have separate igniters that must be tested independently.
Error E021 on the Bosch HGI8056UC 800 Series 30 in Gas Slide-In Range means: Gas Igniter Failure — Broil. The top-ranked community fix is “Test and Replace Broil Igniter Assembly” (hard difficulty, ~60 min, DIY cost: $40-$60). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · oven
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many oven repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $200-$300.
Oven Temperature Sensor Open
Oven Temperature Sensor Shorted
Oven Maximum Temperature Exceeded
Door Lock Fault — Self-Clean
Door Lock Timeout
Gas Igniter Failure — Bake
Gas Valve / Supply Fault
Control Board Communication Error
The Bosch HGI8056UC 800 Series 30 in Gas Slide-In Range has 8 other known error codes: