F3E3
Whirlpool · Whirlpool WED75HEFW 7.4 cu. ft. Electric Dryer with Steam
The inlet temperature thermistor (dryer air inlet sensor) has an open circuit. This sensor measures the temperature of air entering the drum. On some models this sensor is part of the moisture sensor bar assembly. Test and replace similarly to the exhaust thermistor.
Error F3E3 on the Whirlpool Whirlpool WED75HEFW 7.4 cu. ft. Electric Dryer with Steam means: Inlet Thermistor Open Circuit. The top-ranked community fix is “Test and Replace Inlet Thermistor Sensor” (medium difficulty, ~45 min, DIY cost: $15-$25). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · dryer
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many dryer repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $120-$180.
The Whirlpool Whirlpool WED75HEFW 7.4 cu. ft. Electric Dryer with Steam has 8 other known error codes: