9C1
Samsung · Samsung DVG45R6100W 7.5 cu. ft. Gas Dryer with Multi-Steam
The supply voltage is outside the acceptable range. Samsung electric dryers require 240V power. If connected to a 120V outlet or if one leg of the 240V circuit has failed (tripped breaker, loose wire at the outlet or breaker panel), the dryer will display 9C1. Check both legs of the 240V outlet with a multimeter — each should read approximately 120V to neutral. Gas dryers on 120V can also show 9C1 if voltage is abnormally low or high.
Error 9C1 on the Samsung Samsung DVG45R6100W 7.5 cu. ft. Gas Dryer with Multi-Steam means: Voltage Error. The top-ranked community fix is “Measure and Repair Dryer Supply Voltage Issues” (medium difficulty, ~45 min, DIY cost: $10-$20). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · dryer
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many dryer repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $150-$250.
The Samsung Samsung DVG45R6100W 7.5 cu. ft. Gas Dryer with Multi-Steam has 8 other known error codes: