The outgoing water temperature has exceeded the maximum safe limit. The outlet thermistor is reading a temperature higher than the set temperature plus the allowable overshoot (typically above 185°F / 85°C). The unit shuts down immediately to prevent scalding. Causes: (1) Low water flow rate — a partially closed valve, clogged filter, or sediment in the water lines reduces flow, allowing the small volume of water passing through the heat exchanger to overheat. Check and open all isolation valves fully. Clean any inlet water filters. (2) Scale buildup in the heat exchanger — mineral deposits reduce the internal diameter of the heat exchanger tubes, restricting flow and causing localized overheating. Flush the heat exchanger. (3) Stuck bypass servo valve — the bypass valve mixes cold incoming water with heated water to achieve the set temperature. If stuck, inadequate mixing occurs. (4) Faulty outlet thermistor — if the sensor is miscalibrated or reading low, the unit continues to heat past the true set temperature. Check thermistor resistance values against the service manual chart. Error 16 is self-resetting — once the water temperature drops to a safe level, the unit can be restarted.
Error 16 on the Rinnai Rinnai RSC160iN Condensing Combi Boiler means: Over Temperature. The top-ranked community fix is “Flush Heat Exchanger and Test/Replace Outlet Thermistor” (medium difficulty, ~60 min, DIY cost: $5-$20). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · water heater
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many water heater repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $120-$180.
water_heater · 2 fixes
water_heater · 2 fixes
water_heater · 2 fixes
water_heater · 2 fixes
water_heater · 2 fixes
water_heater · 2 fixes
water_heater · 2 fixes
water_heater · 2 fixes
The Rinnai Rinnai RSC160iN Condensing Combi Boiler has 8 other known error codes:
Error code 16 also appears on 8 other Rinnai models:
Ad Space — banner
Replace ADSENSE_PUBLISHER_ID in AdUnit.tsx