LA
Mitsubishi · SUZ-KA09NA 9,000 BTU Concealed Duct System Outdoor Unit
The inverter power transistor (IGBT — Insulated Gate Bipolar Transistor) in the outdoor unit has failed or is operating abnormally. The IGBT is the main switching element that converts DC bus voltage to variable-frequency AC for the compressor motor. Causes: age-related degradation, power surges, sustained overcurrent conditions, heat damage. The inverter board or IPM module requires replacement. This is one of the most expensive outdoor unit repairs.
Error LA on the Mitsubishi SUZ-KA09NA 9,000 BTU Concealed Duct System Outdoor Unit means: Power Transistor (IGBT) Abnormality. The top-ranked community fix is “Replace the Outdoor Unit Inverter Board (IPM Module)” (hard difficulty, ~120 min, DIY cost: $0). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · heat pump
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many heat pump repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $600-$900.
heat_pump · 2 fixes
mini_split · 2 fixes
heat_pump · 2 fixes
heat_pump · 2 fixes
heat_pump · 2 fixes
Reverse Phase / Phase Loss Detection
Compressor Discharge Temperature Protection
Outdoor Heat Exchanger Thermistor Error
Compressor Overheating / High Pressure Switch Activation
Outdoor Subcooling Sensor / Pipe Thermistor Error
High Head Pressure Protection
Compressor Overcurrent Protection (CT Sensor)
Heat Sink / Power Module Overheat Protection
The Mitsubishi SUZ-KA09NA 9,000 BTU Concealed Duct System Outdoor Unit has 8 other known error codes:
Error code LA also appears on 5 other Mitsubishi models: