P6
Mitsubishi · SEZ-KD12NA 12,000 BTU Ceiling-Concealed Ducted Indoor Unit
The indoor coil temperature has dropped below freezing point (cooling mode) or exceeded safe limits (heating mode), triggering protection shutdown. The indoor LED blinks 6 times. In cooling mode, causes include: dirty air filter (most common), dirty blower wheel restricting airflow, low refrigerant charge, indoor fan running too slow, blocked return air grille. In heating mode, causes include: indoor fan failure, blocked discharge. Clean the air filter first — this resolves the majority of P6 faults. If the filter is clean, inspect the blower wheel for heavy buildup.
Error P6 on the Mitsubishi SEZ-KD12NA 12,000 BTU Ceiling-Concealed Ducted Indoor Unit means: Indoor Coil Freeze or Overheating Protection. The top-ranked community fix is “Inspect and Clean Blower Wheel; Check Fan Motor Operation” (medium difficulty, ~60 min, DIY cost: $5-$15). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · mini split
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many mini split repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $120-$180.
mini_split · 2 fixes
mini_split · 2 fixes
mini_split · 2 fixes
mini_split · 2 fixes
mini_split · 2 fixes
mini_split · 2 fixes
mini_split · 2 fixes
mini_split · 2 fixes
Remote Controller PCB Error
Remote Controller Signal Receiving Error
Remote Controller Communication Error
Indoor Unit PCB Processor Error
Indoor/Outdoor Communication Error (Legacy)
Indoor Unit EEPROM Error
Indoor Fan Motor Error
Indoor Unit Overcurrent Protection
The Mitsubishi SEZ-KD12NA 12,000 BTU Ceiling-Concealed Ducted Indoor Unit has 8 other known error codes:
Error code P6 also appears on 8 other Mitsubishi models:
Ad Space — banner
Replace ADSENSE_PUBLISHER_ID in AdUnit.tsx