LC
Mitsubishi · PUZ-HA36NKA5 36,000 BTU Zuba Central Cold-Climate Heat Pump Outdoor Unit
The address EEPROM or data EEPROM on the outdoor unit PCB is corrupted or unreadable. In multi-zone systems, the outdoor unit EEPROM stores the address mapping for connected indoor units. Corruption can cause the outdoor unit to lose track of which indoor units are connected. Try resetting power. If LC persists, the outdoor PCB may need replacement or EEPROM reflashing with Mitsubishi service tools.
Error LC on the Mitsubishi PUZ-HA36NKA5 36,000 BTU Zuba Central Cold-Climate Heat Pump Outdoor Unit means: Outdoor Unit EEPROM / Address Error. The top-ranked community fix is “Replace or Reflash Outdoor Unit PCB to Fix EEPROM Corruption” (hard difficulty, ~90 min, DIY cost: $0). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · heat pump
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many heat pump repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $350-$600.
heat_pump · 2 fixes
mini_split · 2 fixes
heat_pump · 2 fixes
heat_pump · 2 fixes
heat_pump · 2 fixes
Reverse Phase / Phase Loss Detection
Compressor Discharge Temperature Protection
Outdoor Heat Exchanger Thermistor Error
Compressor Overheating / High Pressure Switch Activation
Outdoor Subcooling Sensor / Pipe Thermistor Error
High Head Pressure Protection
Compressor Overcurrent Protection (CT Sensor)
Heat Sink / Power Module Overheat Protection
The Mitsubishi PUZ-HA36NKA5 36,000 BTU Zuba Central Cold-Climate Heat Pump Outdoor Unit has 8 other known error codes: