F29
LG · LRGL5825F 5.8 cu. ft. Smart InstaView Gas Slide-In Range with ProBake Convection
Gas igniter glowed but flame not established within ~90 second safety timeout. Aging igniter draws low current and won't open gas valve. Test igniter amperage (must reach 3.2-3.6 amps). Also check gas supply.
Error F29 on the LG LRGL5825F 5.8 cu. ft. Smart InstaView Gas Slide-In Range with ProBake Convection means: Gas Igniter Timeout. The top-ranked community fix is “Test and Replace the Gas Igniter Assembly” (hard difficulty, ~60 min, DIY cost: $15-$25). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · oven
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many oven repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $120-$180.
Surface Burner Clicks Continuously
Cooktop Burner Won't Light
Control Board Heat Damage
Oven Door Seal Wear
Oven Temperature Sensor Open/Short
Control Board Communication Error
Oven Temperature Runaway
Low Oven Temperature
The LG LRGL5825F 5.8 cu. ft. Smart InstaView Gas Slide-In Range with ProBake Convection has 8 other known error codes: