E2
Lennox · MPA012S4S Lennox Mini-Split Heat Pump System 12,000 BTU
Indoor coil temperature dropped to near-freezing. Causes: dirty air filter (most common), blocked supply/return air, low refrigerant charge, indoor fan at reduced speed. Clean or replace filter. If error recurs with clean filter, check refrigerant charge.
Error E2 on the Lennox MPA012S4S Lennox Mini-Split Heat Pump System 12,000 BTU means: Indoor Coil Anti-Freeze Protection. The top-ranked community fix is “Check Refrigerant Charge and Indoor Fan Operation” (hard difficulty, ~60 min, DIY cost: $0-$20). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · mini split
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many mini split repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $150-$300.
Condensate Drain Blockage / Water Leak
Compressor High Pressure Protection
Compressor Low Pressure Protection
Compressor Discharge Temperature Protection
Compressor Overcurrent Protection
Communication Error — Indoor/Outdoor
Indoor Fan Motor Fault
Indoor Ambient Temperature Sensor Fault
The Lennox MPA012S4S Lennox Mini-Split Heat Pump System 12,000 BTU has 8 other known error codes:
Ad Space — banner
Replace ADSENSE_PUBLISHER_ID in AdUnit.tsx