AGS
Jandy · JXi 260 260,000 BTU Pool Heater with High Efficiency and Digital Temperature Control
The combined air/gas pressure switch detected an abnormal condition — this switch monitors both combustion air pressure and gas manifold pressure; check gas pressure at the heater (natural gas should be approximately 3.5 inches WC supply pressure; LP/propane should be approximately 11 inches WC); check combustion blower operation; check vent system for blockages; gas pressure adjustment requires a licensed technician with a manometer
Error AGS on the Jandy JXi 260 260,000 BTU Pool Heater with High Efficiency and Digital Temperature Control means: Air/Gas Switch Fault. The top-ranked community fix is “Test and Adjust Gas Pressure and Replace Air/Gas Pressure Switch” (hard difficulty, ~90 min, DIY cost: $10-$25). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · pool heater
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many pool heater repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $220-$400.
The Jandy JXi 260 260,000 BTU Pool Heater with High Efficiency and Digital Temperature Control has 8 other known error codes: