8-FLASH
Goodman · GMVM970803BN 80,000 BTU 97% AFUE Modulating Gas Furnace with Variable-Speed ECM Blower
The control board detected an open or short circuit in the hot surface igniter circuit — the igniter is either cracked/broken (open circuit), has a short to ground, or the igniter relay on the control board has failed; silicon nitride igniters are fragile and crack from age, thermal cycling, or physical contact; do not touch igniter surface with bare hands
Error 8-FLASH on the Goodman GMVM970803BN 80,000 BTU 97% AFUE Modulating Gas Furnace with Variable-Speed ECM Blower means: Igniter Circuit Fault. The top-ranked community fix is “Test and Replace the Hot Surface Igniter or Control Board Igniter Relay” (hard difficulty, ~90 min, DIY cost: $40-$100). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · furnace
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many furnace repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $200-$350.
Incorrect Blower Speed / DIP Switch Configuration
Communication Error — ComfortNet Bus
Blower Motor Fault (ECM)
Outdoor Ambient Sensor Fault
System Lockout — Retry Limit Exceeded
Pressure Switch Stuck Closed
Pressure Switch Did Not Close
High Limit Switch Open
The Goodman GMVM970803BN 80,000 BTU 97% AFUE Modulating Gas Furnace with Variable-Speed ECM Blower has 8 other known error codes:
Error code 8-FLASH also appears on 2 other Goodman models: