MECH-GAS-VALVE
Goodman · GMSS920804CN 80,000 BTU 92% AFUE Single-Stage Gas Furnace
The gas valve does not open when commanded by the control board — the igniter glows but no gas flows; verify 24VAC is present at the gas valve terminals during the ignition sequence; if voltage is present but valve doesn't open, the valve has failed; gas valve replacement requires qualified technician and gas leak testing after installation
Error MECH-GAS-VALVE on the Goodman GMSS920804CN 80,000 BTU 92% AFUE Single-Stage Gas Furnace means: Gas Valve Failure. The top-ranked community fix is “Replace Gas Valve and Perform Leak Test” (hard difficulty, ~90 min, DIY cost: $0). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · furnace
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many furnace repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $400-$600.
Incorrect Blower Speed / DIP Switch Configuration
System Lockout — Retry Limit Exceeded
Pressure Switch Stuck Closed
Pressure Switch Did Not Close
High Limit Switch Open
Flame Sensed Without Gas Valve Call
Flame Lost During Operation
Ignition Lockout — Failed to Ignite