F0
GE · JGBS10DEMWW 5.0 cu ft Free-Standing Gas Range
A key on the touch pad (membrane switch) is stuck or the Electronic Range Control (ERC) has detected continuous unintended input from a shorted keypad — press CLEAR/OFF to attempt to cancel; if the code returns after power cycling, the touch pad membrane may have moisture behind it from cooking steam or the membrane itself has failed; the touch pad and ERC (control board) are usually separate parts — try replacing the touch pad first as it is less expensive and more commonly at fault
Error F0 on the GE JGBS10DEMWW 5.0 cu ft Free-Standing Gas Range means: Stuck Touch Pad Key. The top-ranked community fix is “Replace the Touch Pad Membrane” (medium difficulty, ~45 min, DIY cost: $40-$60). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · oven
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many oven repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $150-$220.
oven · 2 fixes
oven · 2 fixes
oven · 2 fixes
oven · 2 fixes
oven · 2 fixes
oven · 2 fixes
oven · 2 fixes
oven · 2 fixes
oven · 2 fixes
Electronic Oven Control (ERC) Failure
Oven Over-Temperature Condition
Open Oven Temperature Sensor (RTD)
Shorted Oven Temperature Sensor
ERC Relay Drive Circuit Failure
Stuck Function Key (Bake/Broil/Clean)
Shorted Meat Probe Circuit
Door Lock Motor Failure
The GE JGBS10DEMWW 5.0 cu ft Free-Standing Gas Range has 8 other known error codes:
Error code F0 also appears on 9 other GE models:
Ad Space — banner
Replace ADSENSE_PUBLISHER_ID in AdUnit.tsx