E1
GE Profile · PFD87ESSVWW Smart Dryer
Dryer temperature sensor (thermistor) open or shorted circuit — monitors drum temperature; test resistance (~10K ohms at room temp, decreasing with heat); replace if open (infinite) or zero
Error E1 on the GE Profile PFD87ESSVWW Smart Dryer means: Thermistor (Temperature Sensor) Failure. The top-ranked community fix is “Test and Replace Defective Inlet Thermistor Sensor” (medium difficulty, ~40 min, DIY cost: $15-$30). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · dryer
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many dryer repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $130-$180.