73
Fujitsu · AOU18RLXFZH 18,000 BTU Multi-Zone Mini Split System with Inverter Compressor
The high-pressure switch has tripped or the discharge pressure has exceeded the safe limit — the most common causes are a dirty outdoor coil (blocking airflow), outdoor fan motor failure, refrigerant overcharge, a non-condensable gas (air) in the system, or extremely high outdoor ambient temperature; clean the outdoor coil with a coil cleaner and garden hose (fin-side out); verify the outdoor fan is running at full speed; check refrigerant charge
Error 73 on the Fujitsu AOU18RLXFZH 18,000 BTU Multi-Zone Mini Split System with Inverter Compressor means: High Pressure Protection. The top-ranked community fix is “Test High-Pressure Switch and Remove Non-Condensables” (hard difficulty, ~90 min, DIY cost: $10-$30). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · mini split
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many mini split repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $150-$220.
mini_split · 2 fixes
mini_split · 2 fixes
mini_split · 2 fixes
mini_split · 2 fixes
mini_split · 2 fixes
mini_split · 2 fixes
mini_split · 2 fixes
mini_split · 2 fixes
Indoor Unit PCB Error
Communication Error — Indoor to Outdoor Unit
Communication Error — Remote Controller to Indoor Unit
Outdoor Unit PCB Error
Outdoor DC Fan Motor Open/Short Circuit
Indoor Fan Motor Lock or Abnormal Speed
Discharge Pipe Temperature Thermistor Error
Indoor Room Temperature Thermistor Error
The Fujitsu AOU18RLXFZH 18,000 BTU Multi-Zone Mini Split System with Inverter Compressor has 8 other known error codes:
Error code 73 also appears on 8 other Fujitsu models: