F1
Dacor · DMW2420S 24 in 1.2 cu ft 1000W Sensor Microwave Oven
The internal temperature monitoring sensor has an open circuit. The microwave uses this sensor to prevent overheating of the cavity, magnetron, and control components. The microwave will shut down as a safety precaution. Disconnect power and check the temperature sensor connections. Measure sensor resistance — it should show a finite resistance at room temperature (not infinite/OL). If the sensor reads open, replace it. Do NOT bypass the temperature sensor — it is a fire safety device.
Error F1 on the Dacor DMW2420S 24 in 1.2 cu ft 1000W Sensor Microwave Oven means: Open Temperature Sensor. The top-ranked community fix is “Test and Replace the Temperature Sensor” (medium difficulty, ~45 min, DIY cost: $15-$25). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · microwave
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many microwave repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $120-$180.