The standby generator controller displays an ATS (Automatic Transfer Switch) fault, indicating the transfer switch did not operate correctly. The ATS is the device that automatically switches the home electrical panel between utility power and generator power. When utility power fails, the ATS should disconnect from the utility and connect to the generator within seconds. When utility power is restored, it transfers back after a time delay. Causes: (1) Mechanical failure — the transfer switch contactors are stuck or worn. Listen for the ATS clicking when it should transfer. If no click, the solenoid coil or contactor mechanism may have failed. (2) Control wiring issue — damaged or loose wires between the ATS controller and the generator. Check all connections at both ends. (3) Utility power issue — the ATS may detect an abnormal utility condition (low voltage, frequency deviation, single-phasing on 240V) and refuse to transfer back to utility. Check utility voltage at the ATS input. (4) ATS controller board failure — the electronic controller inside the ATS has failed. This requires replacement by a qualified electrician. (5) Corrosion on ATS contacts — over time, the contactor surfaces oxidize, causing poor connections or failure to make contact. Regular exercise cycling (weekly) helps keep contacts clean. IMPORTANT: Never bypass or manually override the ATS without proper training — risk of backfeed to utility lines, which is lethal to utility workers.
Error FAULT-ATS on the Champion Champion 100177 8.5 kW 439cc Home Standby Generator with 50A ATS means: ATS Fault — Automatic Transfer Switch Malfunction. The top-ranked community fix is “Replace ATS Contactor Assembly” (hard difficulty, ~90 min, DIY cost: $5-$15). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · standby generator
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many standby generator repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $250-$400.
High Temperature Fault — Engine Overheating
Low Battery Fault — Controller/Starting Battery Voltage Low
Overcrank Fault — Engine Failed to Start Within Crank Time
Overspeed Fault — Engine RPM Exceeded Safe Maximum
Underspeed Fault — Engine RPM Below Minimum Operating Speed
Low Oil Indicator — Automatic Engine Shutdown
ATS Will Not Transfer — Home Stays Without Power During Outage
Starting Battery Will Not Hold Charge
The Champion Champion 100177 8.5 kW 439cc Home Standby Generator with 50A ATS has 8 other known error codes:
Error code FAULT-ATS also appears on 2 other Champion models:
Ad Space — banner
Replace ADSENSE_PUBLISHER_ID in AdUnit.tsx